This Acti9 iC40N is a low-voltage circuit breaker. This is a 1Pol+N circuit breaker with 1 protected pole and a co-switching neutral. It has a nominal current of 32A and a B tripping characteristic. The tripping capacity of this circuit breaker is 6000A at 230VAC according to the standard EN/IEC 60898-1 (household standard) and 10kA at 230VAC according to the standard EN/IEC 60947-2 (industrial standard). This iC40N circuit breaker complies with both the household standard EN/IEC 60898-1 and the industrial standard EN/IEC 60947-2. This circuit breaker protects the electrical circuits against short circuits and overload currents. The handy clip-on function simplifies installation and makes maintenance easier. This Schneider Electric circuit breaker has an electrical life of up to 10,000 cycles and a mechanical life of up to 20,000 cycles. The Ue rated operating voltage is 230VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The network frequency is 50Hz or 60Hz. The circuit breaker can be mounted on a DIN rail for modular installation. The width of this circuit breaker is 1 module of 18mm and the degree of pollution is 3. According to the IEC 60529 standard, the protection degree is IP20. The protection degree increases to IP40 when mounted in a modular housing with insulation class II. The operating temperature is between -25°C and 70°C. The storage temperature is between -40°C and 85°C.
Technical Information
- Voltage type : AC
- Built-in depth : 44 mm
- Rated current : 32 A
- Rated voltage : 230V
- Frequency : 50-60 Hz
- Release characteristic : B
- Rated insulation voltage Ui : 400V
- Current limiting class : 3
- Over voltage category : 3
- Pollution degree : 3
- Width in number of modular spacings : 1
- Degree of protection (IP) : IP20
- Number of protected poles : 1
- Concurrently switching neutral conductor : Yes
- Connectable conductor cross section solid-core : 1-16 mm²
- Connectable conductor cross section multi-wired : 1-10 mm²
- Ambient temperature during operating : -25-70 °C
- Additional equipment possible : Yes
- Number of poles (total) : 2
- Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V : 0 kA
- Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V : 6 kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V : 10 kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V : 0 kA
- Rated impulse withstand voltage Uimp : 4 kV