Miniature Circuit Breaker Acti9 C60H 2Poles C-Curve 10A 440V IP20 Schneider Electric
Watch this product and we will notify you once it is back in stock.
Miniature Circuit Breaker Acti9 C60H 2Poles C-Curve 10A 440V IP20 Schneider Electric
Description
This Acti9 C60H-DC is a low voltage direct current miniature circuit breaker (MCB). It has 2 poles, rated current 10A and C tripping curve. The rated short circuit breaking capacity goes up to 20kA at 220VDC conforming to GB 14048.2 standard and 20kA at 220VDC conforming to GB 14048.2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuit against short circuit and overload current. It offers VisiTrip for safety during maintenance and VisiSafe to reduce intervention time. The Acti9 C60H-DC is used in direct current circuit (industrial control and automation, transport, renewable energy). This device is dedicated to industrial control, automations, transport and renewable energy applications. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 500VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Its width is 4 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.
Technical Information
- Voltage type: DC
- Built-in depth: 44 mm
- Rated current: 10 A
- Rated voltage: 440 V
- Release characteristic: C
- Rated insulation voltage Ui: 500 V
- Current limiting class: 0
- Over voltage category: 4
- Pollution degree: 3
- Width in number of modular spacings: 2
- Explosion-proof: No
- Degree of protection (IP): IP20
- Number of protected poles: 2
- Concurrently switching neutral conductor: No
- Connectable conductor cross section solid-core: 1-25 mm²
- Connectable conductor cross section multi-wired: 1-16 mm²
- Ambient temperature during operating: -25-70 °C
- Flush-mounted installation: No
- Additional equipment possible: Yes
- Number of poles (total): 2
- Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V: 0 kA
- Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V: 0 kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V: 0 kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V: 0 kA
- Rated impulse withstand voltage Uimp: 6 kV
Specifications
- Color: White (RAL9003)