This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 4P RCBO with 4 protected poles, rated current is 32A, and operating voltage is 380VAC to 415VAC. The earth leakage protection class is AC type with a sensitivity of 300mA. The earth-leakage protection time delay is instantaneous. Breaking capacity at 280VAC to 415VAC is 6000A according to EN/IEC 61009-2-1 and 6kA according to EN/IEC 60947-2. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1 standards. Electrical endurance goes up to 10000 cycles, and mechanical endurance goes up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 8. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 70°C.
Technical Information
- Voltage type: AC
- Built-in depth: 45 mm
- Rated current: 32 A
- Rated voltage: 400 V
- Release characteristic: C
- Rated insulation voltage Ui: 500 V
- Rated fault current: 0.3 A
- Leakage current type: AC
- Surge current capacity: 0.25 kA
- Current limiting class: 1
- Over voltage category: 3
- Pollution degree: 2
- Width in number of modular spacings: 4
- Frequency: 50 Hz
- Degree of protection (IP): IP20
- Number of protected poles: 4
- Concurrently switching neutral conductor: Yes
- Rated short-circuit breaking capacity according to IEC 60947-2: 6 kA
- Connectable conductor cross section solid-core: 1-35 mm²
- Connectable conductor cross section multi-wired: 1-25 mm²
- With interlocking device: No
- Ambient temperature during operating: -25-40 °C
- Flush-mounted installation: No
- Number of poles (total): 4
- Anti-nuisance tripping version: No
- Rated impulse withstand voltage Uimp: 4 kV
- Rated short-circuit breaking capacity Icn according to EN 61009-1: 0 kA
- Disconnection characteristic: Undelayed
- Rated short-circuit breaking capacity according to EN 61009: 0 kA
Specifications
- Colour: White (RAL9003)
- Measure(WxHxD): 72x86x78mm